E400 Hybrid Mattress System

One mattress, two levels of care. The E400 is a hybrid mattress designed for adaptable pressure care. Used alone, it offers static foam and air support to help prevent and treat Category 2 injuries. With the addition of a pump, it transitions seamlessly into dynamic alternating therapy, delivering effective treatment up to Category 4.


Adaptable, dependable, and built for evolving care—step up or step down with confidence.

SKU: E400KS
×

Compatible Pump

EP10AU  

Auto-setup, whisper quiet, and safety built-in. The essential alternating pump that works smarter.

Why Clinicians Choose E400  

E400 is chosen for its flexibility. It works as a comfortable hybrid mattress on its own, then steps up to dynamic therapy when paired with a pump. That adaptability makes it ideal for changing clinical needs, remote care, and environments where power access is not always guaranteed. Clinicians trust E400 because it supports both progression and recovery, without forcing an early commitment to powered therapy.

Combines foam and air cell technology for versatile pressure care across varying risk levels.

Clinical Hybrid
1

Core Foam

Five pairs of transverse air cells with foam inserts, encased in a waterproof TPU cover which reduce noise and block fluid ingress.

2

Side Wall Support

Adds stability and edge awareness for safer transfers enhancing comfort, balance and confidence.

3

Stability Core Layer

Supportive base layer enhancing stability, comfort, and pressure relief.

4

Cable Tidy

Integrated channels secure cables for safer bedside setups and protect against wire damage.

5

Accessible Handles

To ensure easy control / transport.

6

Heel Slope

Gentle decline at the foot end reduces heel pressure and helps prevent injuries.

7

Rebound Core Foam

High rebound foam improves airflow and redistributes pressure. Anti Shear top layer moves with the user to protect skin. Heel Offloading foldable foam suspends the heels to relieve pressure and prevent injuries.

8

Pure Guard Cover, Hydro Lock Barrier

Easy to clean, 4-way stretch, vapour-permeable cover that reduces shear and blocks fluids, bacteria, and viruses. Hydro Lock barrier, a welded seam and liquid resistant zip flap prevent fluid penetration, protecting mattress integrity.

Why It Matters 

Care needs are not static. E400 allows clinicians to respond as conditions change, delivering comfort in static use and active pressure redistribution when therapy is required. It reduces unnecessary mattress changes, simplifies workflows, and supports continuity of care across settings. The result is smoother transitions, better comfort, and pressure care that adapts instead of escalating too early.

Technical Specification

Core System & Use 

System Type: Hybrid mattress with paired air cells and profiled foam inserts, supported by a rebound foam layer for airflow and natural movement. 

Clinical Use: 

  • Prevention and management of pressure injuries as a standalone mattress.
  • With the EP10AU pump, delivers alternating pressure therapy suitable for treatment of pressure injuries up to stage 4.

Sizes & Capacity 

  • Mattress Sizes: Single: 88 × 200 × 19.5 cm · King Single: 107 × 200 × 19.5 cm 
  • Firmness & Profile: Medium-firm, 19.5 cm profile 
  • Safe Working Load: Up to 230 kg without pump · Up to 250 kg with pump 

Protection & Safety Features 

Cover Technology 

  • Pure Guard Cover — Four-way stretch, vapour-permeable, antimicrobial surface that reduces shear and supports skin protection.
  • Hydro Lock Barrier — Welded seams and a liquid-resistant zip flap prevent fluid ingress and protect the mattress core.

 

Pressure Relief Features 

  • Anti-shear surface reduces tissue strain 
  • Heel relief zone offloads pressure on vulnerable areas.
  • Reinforced side walls for stability 
  • Satbility Core base with anti-slip underside for secure placement

Warranty

Know Your Mattress

Scroll horizontally to see all products
E400
E500
E600
E700
Features
E400
E500
E600
E700
System Type Hybrid (air-foam)  Alternating Hybrid (air-foam)  Alternating Air (1-in-2 cells)  Advanced Alternating Air (1-in-4 cells) 
Use Clinical  Clinical Pain Relief, Rehab, Palliative Care  High-risk Pressure, Surgical, Frailty  Complex Rehab, Spinal, ICU 
Pressure Injury Stage Stage 1-2 w/o pump, Stage 3-4 with pump Stage 4  Stage 4  Stage 4 
Safe Load 230 KG w/o pump, 250 Kg with pump 230 KG  180 KG 180 KG
Sizes S: 88×200×19.5 · KS: 107×200×19.5 S: 200×88×19.5 · KS: 200×107×19.5 S: 200×90×20 · KS: 200×105×20  S: 200×90×20 · KS: 200×105×20 
Heel Relief Slope
Heel Offload
Static Head Support
Elata Pump EP10AU EP20AU  EP10AU  EP20AU 
Tiltsense™
Up to 12 hr Battery Backup
CPR Valve 
Cable Tidy 
Profile Height  19.5 CM 19.5 CM 20 CM 20 CM

Frequently Asked Questions

At what stage in the pressure care journey is E400 most appropriate?

E400 is most appropriate for clients at moderate to high pressure risk who require more than foam support but may not yet need full alternating air therapy. It sits between clinical foam and advanced alternating systems, offering responsive pressure redistribution with the flexibility to step up if needed.

Can the E400 be upgraded to dynamic therapy if patient needs increase?

Yes. The E400 can be paired with the compatible Elata EP10AU pump to activate dynamic alternating therapy. This allows clinicians to escalate care without replacing the entire mattress, supporting evolving patient needs while protecting long-term investment.

How does the E400 hybrid system differ from a full alternating air mattress?

E400 combines air cells with a supportive foam base, delivering stable comfort with responsive pressure redistribution. Unlike full alternating air systems, it maintains a more familiar sleep surface while offering the option to step into dynamic therapy. It provides balance, greater protection than foam alone, with less complexity than advanced alternating air systems.

View all FAQs here